KVD188B-EM03 LED emergency driver battery installation scheme output power 3W1.5 hours

KVD188B-EM03
Emergency Conversion Kits apply in Led constant current lighting luminaires’ normal lighting or emergency lighting mode, also can be only for emergency lighting purposes.

Emergency lighting solutions provided “charging”, and “discharging” functions, and use intelligent IC controlling circuits, according to be high exchange efficiency and smaller battery capacity.

Internal Li-ion battery, compatible with dimming or non-dimming led luminaire, external installation, emergency supply will be standing and charging by when AC grid electricity supply in normal, will be going to self-maintenance when fully charged, according to longer the battery’s lifespan

The emergency driver will be back up the lighting luminaires within 3 seconds when AC grid electricity stopped, to be sure the light can be working for 1 to 3hrs normally.

KVD188B-EM03 5W-70W LED Emergency Driver Power 90mins 180 mins an energy-saving solution for LED lighting emergency projects, But not for LED tubes . If you are looking for LED Emergency Driver Power kit for LED Light series, please click here

3W LED emergency driver specifications:
1. Emergency Power : 3W
2. Lighting Power: 5W-70W
3. Conversion Efficiency: ≥95%
4. Emergency duration time: 1.5 hours or 2 hours or 3 hours
5. Input Voltage: AC100-277V
6. Output Voltage: DC20-85V
7. Charging Time: 24 hours
8. Working Lifetime(Hour)30000
9. 2years warranty.
10. Best quality and factory price

LED emergency driver Features

Built-in a 18650 legion battery, safe and convenient using.
Energy-saving emergency driver conversion/inverter solution, power the LED light at a low cost power.
Automatically turns on LED lighting when there is a main power failure.
The LED emergency driver battery backup with overcharge and discharge protection, output short protection, overload protection,over temperature protection
With indicator: Green=Main Circuit, Red=Charging.
Each led emergency driver are passed 100% full power load aging test, CE Rosh certified.
Working Environment Attention

Working & storage temperature: -10℃–+45℃(Standard temperature 28℃)
To ensure a longer lifetime, LED emergency battery is needed to be charged and discharged every 3 months.
If stored longer than 3 months in a warehouse, emergency battery is needed to be charged and discharged every 3 months.
Our emergency batteries can be charged/discharged 500 cycles if used in a right way.
Please make sure wire connection is correct before switch on for a long time usage